Skip to main content

AVM treated with Embold™ Fibered​

Presentation

Patient presented to the ER with bilateral AVMs. Multiple right-sided AVMs were treated and the patient scheduled future treatment of the left-sided AVM.

Intervention

An 8 F guiding catheter, 4 F diagnostic catheter and a Direxion HI-FLO microcatheter were placed in the left-sided AVM. Two 14 mm Embold Fibered Coils were placed in the 11 mm nidus, and 10 mm and 8 mm coils were placed in the feeding vessel.   ​

Outcome

The AVM was successfully embolized with Embold Fibered Coils.

300x300 Visualizing the bleed​
300x300 After Embold Fibered placement​

Bret Wiechmann, MD
HCA Florida North Florida Hospital
Gainesville, FL