Skip to main content

AVVIGO™

Guidance System II

The AVVIGO Guidance System II offers high-definition IVUS using the OPTICROSS™ HD Imaging Catheters, along with COMET™ II Pressure Guidewire, all in a sleek mobile or integrated platform.

Key Resources

Explore

  

Product Overview

AVVIGO Guidance System II is a streamlined multi-modality guidance system platform that features intuitive software for an easy workflow and specialized tools for IVUS and coronary physiology. Advanced software features include DFR, smFFR, Trace Assist™, and LongView™ giving physicians the information to properly diagnose ischemia and personalize treatment to ensure the best outcomes.
 

AVVIGO Mobile Platform with Tablet

  • Always ready for your patient, this tablet has an easy-to-use touch screen that starts up in an instant

  • Flexible, set-up configurations for every lab

  • Suite of physiology indices: FFR, DFR, and Pd/Pa

  • SmartMinimum automatically removes artifacts to help you quickly identify the true FFR value
 
 

AVVIGO Integrated System

  • Smaller footprint, providing more space in the cath lab

  • Able to display images on the boom
 

OPTICROSS™ HD and OPTICROSS™ 6 HD 60 MHz Coronary Imaging Catheters

  • High-definition image quality

  • Exceptional deliverability with well-balanced engineering design

  • 5F and 6F compatible to assist in more cases
 
 

COMET II Pressure Guidewire

  • Zero-to-negligible drift performance via optical technology and an enhanced design

  • Shapeable and atraumatic tip designed with Asahi

  • Free-spinning, quick-release handle

  • Optimized rail support for device delivery
 
 

FFR Link

  • Simple bedside mount

  • Compatible with your hemodynamic system

  • Seamless Bluetooth connection with either AVVIGO Guidance System
  

Advanced Software Features

 
DFR

DFR

DFR calculates a diastolic portion of the cardiac cycle at rest. DFR uses a cutoff of 0.89 and is numerically equivalent to iFR. The DFR window uses two criteria: Pd < mean Pa and down-sloping Pa. No ECG signal is required.

smFFR

smFFR

smFFR automatically excludes certain artifacts (e.g., flushing, opening AO stopcock or hemostasis valve, pulling out guidewire during recording) to latch to the true FFR value.

 
Trace Assist™

Trace Assist™ 

An aid to automatically draw lumen and vessel borders.

LongView™

LongView™ 

IVUS LongView provides a user the ability to guide PCI with length measurements and visualization of bifurcations.

 

AVVIGO vs AVVIGO II

AVVIGO Guidance System is for physiology only users. It is an easy to use, tablet based platform that seamlessly integrates with FFR Link and our workhorse COMET II Pressure Guidewire to provide a suite of resting and hyperemic physiology measurement.
 
Feature AVVIGO AVVIGO II
Mobile Platform with Tablet

✔️

✔️

Integrated Platform  

✔️

OPTICROSS HD, 6 HD 60 MHz Imaging Catheters  

✔️

COMET II Pressure Guidewires

✔️

✔️

FFR Link

✔️

✔️

DFR Software

✔️

✔️

smFFR Software

✔️

✔️

Trace Assist Software  

✔️

LongView Software  

✔️

 

Ordering Information

Description GTIN Ref/Catalog Number

AVVIGO Guidance System II Mobile Cart System

00191506015152 H749 009881C 0
AVVIGO Guidance System II Integrated System 00191506015183 H749 009881I 0
AVVIGO Guidance System 08714729996538 H749 009761 0
FFR Link 08714729890010 H749 555100 0
COMET II Pressure Guidewire 08714729960140 H749 3935911 0
OPTICROSS HD Imaging Catheter 08714729960737 H749 3935204 0
OPTICROSS 6 HD Imaging Catheter 08714729960775 H749 3935408 0
OPTICROSS Imaging Catheter 08714729847878 H749 51811 0
OPTICROSS 6 Imaging Catheter 08714729904762 H749 518116 0
OPTICROSS 18 Imaging Catheter 08714729904266 H749 393280018 0
OPTICROSS 35 Imaging Catheter 08714729984542 H749 393280035 0
ULTRA ICE PLUS Imaging Catheter 08714729904380 M004 9912 0
Automatic Pulback Sled 08714729339328 H749 A7020 0
MDU5+ Motor Drive 08714729842279  H749 MDU5PLUS 0
MDU5+ Sterile Bag 08714729842255 H749 MDU5PLUSBAG 0
  

Reimbursement

The C-code for the COMET II Pressure Guidewire is 1769. The C-code used for the OPTICROSS HD and OPTICROSS 6 HD 60 MHz Imaging Catheters is C1753. C-codes are used for hospital outpatient device reporting for Medicare and some private payers.

Visit our GuidePoint reimbursement site for more information

Note: Boston Scientific Corporation is not responsible for correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice.

AVVIGO ExpertCare Service Programs

We have a shared mission—to keep your capital equipment running at the highest level, so you always maintain the highest level of care for your patients. From Essential Care to EVERCARE Plus, we have several tiers of service tailored to meet your budget and any challenge that comes along.
Technical Support 1-800-949-6708
 

EVERCARE or EVERCARE PLUS

EssentialCare

Phone Support Service

 

 

Unlimited access to technicians via phone

24/7 phone support during patient procedures

Performance Maintenance

 

 

Software updates and bug fixes

Annual preventative maintenance

✔*

Repair Services

 

 

Unlimited repair visits

Labor and travel coverage

Complete parts coverage

48-hour part shipping

Additional Program Features

 

 

Priority designation

X

Hardware upgrade

X

Software upgrades

X

Coverage for up to 5 FFR Links

X

*Preventative Maintenance included only with AVVIGO Guidance System II, not AVVIGO Guidance System
 